#12021-12-03 08:10:57

TBHU4566
Member
Registered: 2021-12-03
Posts: 2

When ECP is used, net charge is introduced in Fuzzy atomic analysis.

Recently, I do some test by ORCA. The system is an I2(iodine) molecule. I transfer the .gbw to .molden file. And I also change the nuclear charge of I from 53 to 25. But when I use Fuzzy atomic analysis (function 15 in Multiwfn), wrong dipole moment is obtained. And the net charge is -56.0000. If I change the nuclear charge of I to 53, the net charge is +56.0000. I don't know why?

Offline

#22021-12-03 11:08:31

sobereva
Tian Lu (Multiwfn developer)
From: Beijing
Registered: 2017-09-11
Posts: 1,773
Website

Re: When ECP is used, net charge is introduced in Fuzzy atomic analysis.

I don't find this problem in using subfunction 2 of main function 15.
Clipboard01.png

This is my modified .molden file

Clipboard02.png

I am using latest version of Multiwfn and ORCA 5.0.1. Please make sure you are using latest version of Multiwfn.

Offline

#32021-12-06 02:32:53

TBHU4566
Member
Registered: 2021-12-03
Posts: 2

Re: When ECP is used, net charge is introduced in Fuzzy atomic analysis.

Dear Tian Lu,
Thank you for your help!! I change the Multiwfn version from 3.7 to 3.8. The problem has been solved.

QQ-20211206103159.png
Best wishes,
Bo Tang